Lyell Collection

Quarterly Journal of Engineering Geology and Hydrogeology

Lyell Centre  |   Lyell Collection  |   Subscriptions   |   Geological Society  |   Email alerts  |   Online bookshop  |   Help


Keywords:
Author:
Advanced search>>
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Toynton, R.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation
Quarterly Journal of Engineering Geology and Hydrogeology; 1983; v. 16; issue.3; p. 169-185;
DOI: 10.1144/GSL.QJEG.1983.016.03.02
© 1983 Geological Society of London

Article

The relation between fracture patterns and hydraulic anisotropy in the Norfolk Chalk, England

R. Toynton

Scunthorpe Museum & Art Gallery, , Oswald Road, Scunthorpe, South Humberside DN15 7BD

Structurally the Chalk in Norfolk forms a relatively uniform aquifer and it is therefore possible to distinguish between aquifer inhomogeneity and anisotropy in this area. This has been achieved by comparing directional transmissivity values with the fracture pattern in the Chalk. A map of fracture directions has been constructed for the whole of the Norfolk Chalk.

Aquifer properties have been calculated as areal values, point values, and directional point values. The ability to represent aquifer anisotropy by transmissivity ellipsoids has been extended to allow prediction of properties, and, through the use of the mean radius of the ellipsoid, comparisons between point values over an area.

A family of ellipsoid curves has been developed which summarize and aid analysis of transmissive anisotropy over an area.

A comparison of fracture orientations with point and areal transmissivity ellipsoids shows not only that the anisotropic nature of the aquifer is a direct result of the fracturing but also that this behaviour can be predicted by studying the fracture pattern and vice versa.




This article has been cited by other articles:


Home page
Geological Society, London, Special PublicationsHome page
I. Yusoff, K. M. Hiscock, and D. Conway
Simulation of the impacts of climate change on groundwater resources in eastern England
Geological Society, London, Special Publications, 2002; 193: 325 - 344.
[Abstract] [PDF]


Home page
Quarterly Journal of Engineering Geology and HydrogeologyHome page
S. Barnes
Karstic groundwater flow characteristics in the Cretaceous Chalk aquifer, Northern Ireland
Quarterly Journal of Engineering Geology and Hydrogeology, 1999; 32: 55 - 68.
[Abstract] [PDF]


Home page
Quarterly Journal of Engineering Geology and HydrogeologyHome page
P. L. Younger and T. Elliot
Chalk fracture system characteristics: implications for flow and solute transport
Quarterly Journal of Engineering Geology and Hydrogeology, 1995; 28: S39 - S50.
[Abstract] [PDF]


Home page
Geological Society, London, Special PublicationsHome page
A. M. Goodwin
Spatial change in joint geometry in the Chalk of eastern England
Geological Society, London, Special Publications, 1995; 92: 197 - 213.
[Abstract] [PDF]


Home page
Journal of the Geological SocietyHome page
T. G. BEVAN and P. L. HANCOCK
A late Cenozoic regional mesofracture system in southern England and northern France
Journal of the Geological Society, 1986; 143: 355 - 362.
[Abstract] [PDF]