Lyell Collection

Quarterly Journal of Engineering Geology and Hydrogeology

Lyell Centre  |   Lyell Collection  |   Subscriptions   |   Geological Society  |   Email alerts  |   Online bookshop  |   Help


Keywords:
Author:
Advanced search>>
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kitching, R.
Right arrow Articles by Adams, B.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation
Quarterly Journal of Engineering Geology and Hydrogeology; 1986; v. 19; issue.2; p. 143-154;
DOI: 10.1144/GSL.QJEG.1986.019.02.07
© 1986 Geological Society of London

Exotic uses of aquifers

Thermal energy storage studies in the Lower Greensand aquifer in Cambridgeshire

R. Kitching & B. Adams

British Geological Survey, , Maclean Building, Crowmarsh Gifford, Wallingford, Oxon OX10 8BB

A field experiment has been carried out in the Lower Greensand near Cambridge to test the feasibility of injecting, storing and recovering heat in this formation. Approximately 1500 m3 of water at about 60°C were injected into the Lower Greensand over a period of 78 days. After storage for 105 days, the heat was abstracted over a period of 97 days. Over this single cycle of operation 33% of the injected energy was recovered. This proportion is likely to increase significantly with further injection/abstraction cycles. Increasing the amount of heat injected was also thought likely to reduce losses and increase the proportion of heat recovered.

A digital model of the Aquifer Thermal Energy Storage (ATES) system was set up and calibrated on the Cray IS system at the University of London Computer Centre. It was then used to predict the behaviour of larger ATES systems both on inter-seasonal and diurnal bases. Energy recovery factors of over 66% appear to be feasible.